Sys ex control #287

Open
wants to merge 28 commits into
base: main
Choose a base branch
from
Open

Conversation

BenZonneveld
Copy link

Several improvement in sysex control.
All instances get a fixed sysex channel as not to cause any conflicts.

@probonopd
Copy link
Owner

probonopd commented Jun 20, 2022

Hi @BenZonneveld, thank you very much.
I am a bit puzzled by the build error.
Can you build it locally for the Raspberry Pi 4?

@BenZonneveld
Copy link
Author

Replace my build.sh with the original. For testing I removed the extracting of the arm compiler and rebuilds of circle

@probonopd
Copy link
Owner

Can you please change that in https://github.com/BenZonneveld/MiniDexed/tree/SysExControl? Then the build in this Pull Request should "magically" start working.
Thanks!

@probonopd
Copy link
Owner

Something weird is going on with the git submodules:

Cloning into '/home/runner/work/MiniDexed/MiniDexed/CMSIS_5'...
Cloning into '/home/runner/work/MiniDexed/MiniDexed/Synth_Dexed'...
Cloning into '/home/runner/work/MiniDexed/MiniDexed/circle-stdlib'...
Submodule path 'CMSIS_5': checked out '8a64562247485159a090ec4a01588f44f8d10311'
fatal: remote error: upload-pack: not our ref a3a696b003ef76f79dbd91ff8188a[12](https://github.com/probonopd/MiniDexed/runs/6975070899?check_suite_focus=true#step:3:13)3b74e5e17
fatal: Fetched in submodule path 'Synth_Dexed', but it did not contain a3a696b003ef76f79dbd91ff8188a123b74e5e17. Direct fetching of that commit failed.
Error: Process completed with exit code 128.

@probonopd
Copy link
Owner

probonopd commented Jun 20, 2022

@BenZonneveld would this fix
asb2m10/dexed#352?

@BenZonneveld
Copy link
Author

No...actually I removed the sending of sysex voices and only send the sysex on a patch request sysex, as it should be.
A program change shouldn't send a sysex with a voice dump.

@dcoredump
Copy link
Contributor

No...actually I removed the sending of sysex voices and only send the sysex on a patch request sysex, as it should be.
A program change shouldn't send a sysex with a voice dump.

I had added this because then the editors immediately display the correct data. Maybe this should be made configurable via minidexed.ini, because I found it a great help so far.

@probonopd
Copy link
Owner

Yes, we should definitely not remove this feature!

@BenZonneveld
Copy link
Author

No...actually I removed the sending of sysex voices and only send the sysex on a patch request sysex, as it should be.
A program change shouldn't send a sysex with a voice dump.

I had added this because then the editors immediately display the correct data. Maybe this should be made configurable via minidexed.ini, because I found it a great help so far.

Still, the normal way for an editor would be to do a patch request. It is what my MiniDexed master does: receive pgm change, request voice data.

If you always send the sysex voicedump it would mean I can never use MiniDexed with for example my DX7

@probonopd
Copy link
Owner

It could be made configurable.

@BenZonneveld
Copy link
Author

And there we have a building branch with my patches.

@probonopd
Copy link
Owner

probonopd commented Jul 6, 2022

It builds! 👍

Can you describe what exactly this PR fixes/improves?

I figured out:

  • More MIDI commands received via serial are interpreted
  • More MIDI control change messages are sent via serial
  • Convert NL+CR to NL on serial output

@probonopd
Copy link
Owner

probonopd commented Jul 17, 2022

Would #311 do the same job instead of having a private copy of Circle's serial.h? If possible I would like to avoid a private copy of that file, in order not to have the burden of maintenance. It looks to me like #311 also converts NL+CR to NL on serial output, but without the need for a patched serial.h.

@probonopd
Copy link
Owner

I had added this because then the editors immediately display the correct data. Maybe this should be made configurable via minidexed.ini, because I found it a great help so far.

...or we ask editors (yes I am thinking of you, Dexed) to send a patch request, like @BenZonneveld is saying? This is probably the way it should be done in MIDI.

@psethwick
Copy link

I tracked down the reason that my M-Audio Oxygen49 quits working after a program change to: receiving the sysex data afterwards, so +1 for configuration parameter, at least!

My keyboard probably shouldn't crash, but, well, it does. Probably something to do with its own memory dump feature.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment